Skip to content
Qualiyoo
THE QUALIYOO STANDARD

185 checkpoints. Every one measured, photographed and verified.

QS-185™ is our written standard for building quality, from setting out to handover. A G+3 building gets 293 checks across 12 site visits, because columns and slabs are checked again on every floor.

₹2,000 per visit for buildings up to 3,000 sqft. Free re-inspection until it passes.

QS-04-04 · Lap length
Column C3 · First floorMain bar lap, from your column schedule
Bar diameter16 mm
Lap on drawing50 × bar diameter
Required lap800 mm
Measured on site720 mm
720 mm

Photo taken in the app, tape in frame, location and time recorded.

  • 185checkpoints in the standard
  • 14construction stages covered
  • 15visit stages, two of them repeated on every floor
  • 80checks rated critical

Every stage, from the first string line to handover

Each checkpoint says what to check, how to test it, what passes, and which IS code it comes from. Tap a stage to see real checkpoints.

Tap a stage to see sample checkpoints.

What one check looks like

Here is a real checkpoint from the standard: lap length in a first-floor column.

  1. 1

    The rule

    Where two bars overlap, the overlap must be at least the lap length on your structural drawing, usually 40 to 50 times the bar diameter (IS 456, Cl. 26.2.5). Here the drawing asks for 50 ×, so a 16 mm bar needs 800 mm.

  2. 2

    The value comes from your drawing

    Before the visit we load your column schedule, so the engineer’s tablet already shows 800 mm.

    QS-04-04 · Lap length
    Column C3 · First floorMain bar lap, from your column schedule
    Bar diameter16 mm
    Lap on drawing50 × bar diameter
    Required lap800 mm
    Measured on site— mm

    Value loaded before the visit. The engineer measures; the app applies the rule.

  3. 3

    The engineer measures

    On site the lap measures 720 mm. The engineer types the reading and takes a photo with the tape in frame.

    QS-04-04 · Lap length
    Column C3 · First floorMain bar lap, from your column schedule
    Bar diameter16 mm
    Lap on drawing50 × bar diameter
    Required lap800 mm
    Measured on site720 mm
    720 mm

    Photo taken in the app, tape in frame, location and time recorded.

  4. 4

    The app decides

    720 is less than 800, so the check fails and the pour has to wait. The engineer can’t override it.

    QS-04-04 · Lap length
    Column C3 · First floorMain bar lap, from your column schedule
    Bar diameter16 mm
    Lap on drawing50 × bar diameter
    Required lap800 mm
    Measured on site720 mm
    720 mm
    FAIL720 mm is less than 800 mm. The pour waits. Cannot be overridden on site.
  5. 5

    Everyone knows, and it gets fixed

    The owner and contractor get the photo, the reason and the fix on WhatsApp. After re-lapping, we re-inspect free before the pour.

    QS-04-04 · Lap length
    Today, 11:42
    Qualiyoo QA · Check failedColumn C3, first floor. Lap length 720 mm; the drawing needs 800 mm.Fix: extend the lap to at least 800 mm before the pour.The pour waits. We re-inspect free once it is fixed.
    Sent to the owner and the contractor
    QS-04-04 · Lap length
    Column C3 · First floorMain bar lap, from your column schedule
    Bar diameter16 mm
    Lap on drawing50 × bar diameter
    Required lap800 mm
    Measured on site820 mm
    820 mm
    PASSRe-inspected after re-lapping: 820 mm ≥ 800 mm. The pour can go ahead.

Built for contractors who want to prove their work

  • 1

    Stage bills backed by proof

    Send your client our stage report with your next bill. Every check, photo and reading is there.

  • 2

    Win jobs against cheaper rivals

    Show past Qualiyoo reports to new clients. It shows them your sites are checked by someone independent.

  • 3

    Catch mistakes while they are cheap

    A short lap found before the pour costs a few bars. Found after, it costs a column.

Why you can trust the report

Our engineers don’t work for you or your client. They work to the standard.

Four checks on every visit

  • The engineer is inside your site’s location boundary for the whole visit.
  • Time on site is above the minimum for that visit.
  • Every photo is taken in our app, never uploaded from a phone gallery.
  • No photo is reused from an earlier visit.

Checks come from Indian Standards

Number of checkpoints that cite each code.

  • IS 45647
  • IS 166111
  • IS 73210
  • IS 221210
  • IS 17429
  • IS 30679
  • IS 19046
  • IS 23956
  • IS 12005
  • IS 20654

Look at the report before you book

EXAMPLE DATAV05 · Columns · First floor
Verdict: pour waits, 1 issue15 of 16 passed
QS-04-04CriticalLap length 720 mm at column C3; drawing needs 800 mmAction: extend the lap before the pour · Responsible: contractor’s site engineer
  • Main bar diameter, number and gradePASS
  • Lap lengthFAIL
  • Concrete grade, slump and cubesPASS
  • Finish after de-shutteringPASS

Page 1 of a visit report: the verdict, the issue found, and the key checks for that stage.

Get a sample report

We’ll send a full sample report to your WhatsApp and email. We use your details only for this and to follow up about QA visits.

Simple price per visit

Built-up areaPrice per visit
Up to 3,000 sqft₹2,000
3,000 – 6,000 sqft₹2,800
6,000 – 10,000 sqft₹4,000
[+ GST / incl. GST]

Each visit includes

  • A checklist for that stage
  • Readings and photos for every checkpoint
  • Every issue graded minor, major or critical
  • A corrective action list naming the person responsible
  • A written report within 24 hours
  • A WhatsApp alert for any failed check
  • Free re-inspection until it passes

Book a QA visit

Questions

What happens if a check fails?

You get the photo, the reason and the fix on WhatsApp. Once fixed, we come back and re-check it free.

When do I get the report?

Within 24 hours of every visit. Every issue is graded minor, major or critical, with a corrective action list that names the person responsible for each fix.

Who are the engineers?

Civil engineers with [qualification] and at least [X] years of site experience.

Do I need drawings?

Yes. Checks such as bar size, lap length and cover are measured against your structural drawings. We load them before the first visit.

Which cities do you work in?

Chennai and Bangalore.

Can the engineer pass something that fails?

No. The engineer records the reading and the app applies the rule.